ELOUF-101
Microprocessor based system to monitor frequency changes
Microprocessor based system to monitor frequency changes in a 3 phase power supply.
- Selectable over and under frequencies from 45Hz to 55Hz
- One change over contact
- Definite time selection from 0.1 sec to 10 sec
- User friendly menu to set the frequency monitoring limits
- LED based display screen to display 3 frequencies in real time
Temperature Display Unit (ELTM-101)
Temperature Display Unit (ELTM-101)
This temperature display unit uses three solid state temperature sensors to measure the temperature from three different areas of interest and displays them on three separate 7-Segmet displays accordingly.
The built in alarm and relay may be energized for selectable settings. Relay temperature range is adjustable between 20°C to 100°C.
3 LEDs for each temperature display, One LED display for the Alarm.
Over current Earth fault relay (OCEF-102)
Over current Earth fault relay (OCEF-102)
-
- True RMS measurement
- Selectable IDMT curves Plus DTL
- 2 programmable contacts
- Recording of time tagged events, up to 15 Events
- Real time display of current
- Built in Real time clock with back-up power
- 9 No.s of status LEDs
- Pre Alarm Indications
- Software lock to prevent unauthorized data entry
- Internal battery status display
- Complies with IEC 60255-26 and ANSI 50P, 51P
- Programmable parameters through LAPTOP connection.
Three phase voltage protection Relay (ELV-380)
Three phase voltage protection Relay (ELV-380)
- Power system faults such as over-voltage, under voltage (brown out), voltage unbalance, and single phasing are becoming more and more common due to ever-increasing demands being placed on power distribution systems.
- ELV-380 provides a comprehensive protection against all of the above.
- The device is also available for 110V power systems.
DC Under Voltage Relay (ELUV-110)
DC Under Voltage Relay (ELUV-110)
- This relay monitors the condition of DC voltage continuously and indicates a “drop in voltage” if the DC voltage level drops to 80% of the nominal value.
- It can be used to monitor the voltage level in systems that use batteries as backup source or in general, where ever the monitoring of DC voltage level is critical.
DC Over and Under Voltage Relay (ELOUV-110)
DC Over and Under Voltage Relay (ELOUV-110)
- This relay monitors the condition of DC voltage continuously and indicates:
- “Drop in voltage” if the DC voltage level drops to 80% of the nominal value.
- “Increase in voltage” if the DC voltage level rises to 120% of the nominal value.
- It can be used to monitor the voltage level in systems that use batteries as backup source or in general, where ever the monitoring of DC voltage level is critical.
No Volt Relay (ELNV-110)
No Volt Relay (ELNV-110)
- Version (1) This relay can stay energized till 9 VAC . the relay is dropped below 9 volts AC.
- Version (2) It is also available for 220 VAC three phase systems, where the relay contact is dropped at 290Volts L-L and picked at 353 Volts L-L. (as per WAPDA specs).
- These relays are self-powered, so no need of any auxiliary supply.
Super Saver
Super Saver
- Super-fast (less than 20 milliseconds) Protection against:
- Voltage surge
- Neutral loss
- Over voltage
- Long duration transients
- Under voltage
- Super Saver resets automatically after voltage supply normalizes, therefore no need for frequent replacement, as required by other similar devices
MP380
MP380
A rule of thumb in industry to measure the decrease in motor life expectancy is that for each 10 degrees centigrade of operating temperature increase, the life expectancy of the motor insulation decreases by 50%. A fairly comprehensive, microprocessor-based solution to protect expensive motors is offered by E-Labs. MP380 provides the much needed monitoring of the supply before starting the motor and while it is running.
Technical Specifications:
- Main Supply
- Phase to Phase
- Under-Voltage Selection
- 330,340,350,360
- Over-Voltage Selection
- 415,430,445,460
- Power Consumption
- 1 watt
- Dropout time
- 2.5 seconds (Adjustable)
- Pickup time
- 3 seconds
- Relay contacts
- SPDT. Type, 250VAC 5Amps
- Housing
- Plastic casing
- Unbalance
- Dropout at 11% and reset at 6%
ELOCR-60
ELOCR-60
MODELS | ELOCR-60 | |||
Current Range | 3.0-60.0 Amperes | |||
Time Settings | START UP DELAY TIME | 1 – 50 seconds | ||
TRIPPING TIME | 1 – 10 seconds | |||
Accuracy | Current | ±2% | ||
Time | ±2% of set value | |||
Time Characteristics | Definite Time | |||
Control Voltage | 160 VAC TO 260 VAC, 50/60Hz or
12 VDC, 24VDC. |
|||
Current Sensing | Internal Current transformers | |||
Output Contacts | 1 NO. & 1 NC. | SPDT 5A/250VAC resistive | ||
Reset | Manual push button or remote electrical by interrupting supply | |||
Environment | Temp. | Run | -20 + 70 deg. °C | |
Store | -30 + 70 deg. °C | |||
Humidity Between casing and circuits: | 45 ~ 85% RH, Non-condensing | |||
Insulation | Over 10M Ohms with DC600V megger | |||
Dielectric Strength | 1. Between casing and circuits: AC 2000V, 50Hz, 1 min.
2. Between contacts: AC 1000V, 50Hz, 1 min. 3. Between circuits : AC 2000V, 65Hz, 1 min. |
|||
Power Consumption | 3W | |||
Mounting | Din rail | |||
The run-up current of motor (starting current) does not cause relay trip because overcurrent protection of this product is not applied during motor start-up time. |
AM-101
AM-101
Annunciation Module (AM101) is a highly reliable processor based annunciation system. The Processor based architecture allows for easy customization of the operation and considerable reduction in size. This compact system offers multi-event annunciation in response to the input fault signal. The fault signal voltage can vary from 220,110,60,48,24 VDC or VAC.
SIR-110
SIR-110
STATUS INDICATION RELAYS (SIR-101) is highly reliable processor based annunciation system. The processor based architecture allows for easy customization of the operation and considerable education in size. This compact system offers multi-event annunciation in response to the change in the status of the system being monitored. The fault signal voltage can vary from 220,110,60,48,24 VDC or VAC.
TRIP CIRCUIT AND DC VOLTAGE SUPERVISION RELAY (TS-101)
TRIP CIRCUIT AND DC VOLTAGE SUPERVISION RELAY (TS-101)
- Continuous supervision of trip circuits with circuit breaker in the open and closed position. Monitors loss of auxiliary voltage, DC trip voltages, and circuit interruptions.
- Indicating flag, (LED)
- Tripping output contacts, N/O or N/C.
- Plastic casing for flush mounting.
- Delayed drop-off to prevent spurious operation.
- Does not require any external resistor.
- Mechanical Flag to indicate loss of DC Voltage or any other fault.
Under and Over Frequency Protection Relay (ELFR-50)
Under and Over Frequency Protection Relay (ELFR-50)
Frequency Protection Relay takes the reliable measurement of frequency. User can set the over and under frequency limits through selection variables, crossing these limits shall operate a relay rated at 5A AC.
Battery Impedance Monitoring Relay (ELBI-220)
Battery Impedance Monitoring Relay (ELBI-220)
- For DC-Voltage systems, it protects the system against deterioration of battery impedance. The cause of which could be terminal corrosion, loose terminal connections, sulphate deposit etc.
- On pressing of start button, it measures the resistance between battery terminals by drawing 10 amps for a short duration and measure the impedance simultaneously.
CAPACITOR TRIP UNIT (ELC-110)
CAPACITOR TRIP UNIT (ELC-110)
- CAPACITOR TRIP UNIT (ELC-110) takes AC supply for input, converts it into DC Voltage. At the absence of AC Supply it holds enough power to supply 130 VDC and 3Amps for 3 to 4 seconds.
- A discharge button is provided, in case maintenance work needs to be done.
BATTERY EARTH FAULT RELAY (ELEF-110)
BATTERY EARTH FAULT RELAY (ELEF-110)
- BATTERY EARTH FAULT RELAY (ELEF-110) is used in DC-Voltage systems, it protects the system against leakage of current to earth.
- It continuously monitors the resistance between earth and both the poles, and as the resistance
drops to a preset level the contact makes and the visual indication comes on. - The Relay is available in 48,110 and 220 Voltage range
The Hygrostat Relay (ELH-220)
The Hygrostat Relay (ELH-220)
- The Hygrostat Relay ELH-220 is a microprocessor based intelligent relay that monitors and control the inside humidity level of the panel containing electrical equipment.
- It does that by measuring the humidity level, compares it with the preset limit and energizes the heater through its dry contact, whenever needed, till the humidity level drops to the desired level.
- It has built-in thermostat (adjustable) and a contact to energize the external heater.
Transformer Temperature Gauges (XTP3)
Transformer Temperature Gauges (XTP3)
- Transformer Temperature Gauges XTP-3 is for the protection of heavy transformers against overheating. However, it may be used for protecting large motors and generators as well.
- It is utilized in conjunction with a semiconductor-based thermal sensor, which is placed at a strategic spot in the equipment to detect sustained operating temperatures above normal.
- The rugged sheet metal body allows for its mounting in panels next to the transformers primarily designed.
Transformer Tap Display
Transformer Tap Display
Stabilizer
Stablizer
- Brand Warranty
- Input voltage: 160V~270V
- Output voltage: 220V ±5%
- Frequency: 50 Hz/ 60hz
- Phase: Single
- Response Time: < 0.5 sec
- Power factor: better than 90%
- Over Voltage protection after 270VAC